See the documentation for PPL TXLINT:
txlint,low,high time axis lab intervals (0,1=yr only; 1,0=mon
only; 3,1=every 3 mon+yr)
You can force the issue with PPL TICS:
tics,smx,lgx,smy,lgy,ix,iy sm(x,y)=small tic size (0.125)
lg(x,y)=large (0.25)
For long-forgotten reasons, TXLINT is a single-plot command, but TICS
is persistent.
Billy K
On Apr 16, 2007, at 3:53 PM, Stephens, A (Ag) wrote:
Dear all,
Can you tell me how to remove the minor tic marks (those at 6-hourly
intervals in the attached plot) from a variable versus time line plot?
I want to keep the dates as the major label and tic mark but remove the
smaller tics.
Thanks,
Ag
--Ag Stephens Tel: +44 (0)1392 884263
BADC - UK Met Office Coordinator Fax: +44 (0)1392 885681
Met Office, A2 - 05, FitzRoy Road, Exeter, EX1 3PB, UK.
E-mail (BADC): a.stephens@xxxxxxxx
E-mail (Met Office): ag.stephens@xxxxxxxxxxxxxxxx
Home page: http://home.badc.rl.ac.uk/astephens
BADC details:
British Atmospheric Data Centre, Rutherford Appleton Laboratory,
Chilton, Didcot, OX11 0QX, UK. http://badc.nerc.ac.uk
<2007040900_arba_minch_rainfall.gif>