17 Degree Isotherm Depth: The depth of the 17 degree (C) isotherm is calculated from temperature profiles using linear interpolation of depth vs temperature. The maximum distance between temperatures is 50m, and is typically 20 or 25 meters. In ascii format files, to the right of the data, you will find data quality codes which use the definitions below. Using these codes you can tune your analysis to trade-off between quality and temporal/spatial coverage. Quality Code Definitions: 0 = datum missing 1 = highest quality; Pre/post-deployment calibrations agree to within sensor specifications. In most cases only pre-deployment calibrations have been applied 2 = default quality; Pre-deployment calibrations applied. Default value for sensors presently deployed and for sensors which were either not recovered or not calibratable when recovered. 3 = adjusted data; Pre/post calibrations differ, or original data do not agree with other data sources (e.g., other in situ data or climatology), or original data are noisy. Data have been adjusted in an attempt to reduce the error. 4 = lower quality; Pre/post calibrations differ, or data do not agree with other data sources (e.g., other in situ data or climatology), or data are noisy. Data could not be confidently adjusted to correct for error. 5 = sensor or tube failed